How to replace the convection micro motor
Resolution

Refer always to your product’s user manual safety information before any repair or maintenance operation. https://www.electrolux.com/support/user-manuals/

WARNING! RISK OF ELECTRIC SHOCK
Before any repair or maintenance operation, deactivate the appliance and disconnect the mains plug from the socket.


WARNING! RISK OF INJURY

Always take care when moving appliances. For heavy appliances it's safest for two persons to move it. Always use safety gloves and safety footwear. Wear safety gloves at all times to protect from cuts from sharp edges.

WARNING! RISK OF EYE INJURY

Wear safety glasses if you perform maintenance or repair work involving springs.

WARNING! RISK OF BURNS
Before any repair or maintenance operation make sure the appliance is not hot.

WARNING! CHOKING HAZARD
Small parts not for children under 3 years. Keep all small parts and packaging out of reach of children.
Only adults should use or install the product.
Make sure to use the product only for its designated purpose and verify that it is a compatible part for the intended product.
Do not use or install the product if damaged.
Please note that self-repair or nonprofessional repair can have safety consequences if not done properly and might void the warranty. Possessing the necessary know-how is essential.
HOW TO REPLACE CONVECTION MICRO-MOTOR
Before replacing any part of the appliance remove the door when the appliance is still mounted in the furniture. Door removal is described in the User Manual.
Screw placement and their number may differ depending on appliance.
1. Unscrew the screws on the rear panel and then lift the rear panel out of its holding tabs to release. (NOTE: Ensure all tabs are correctly refitted during reinstallation).


2. Unscrew the screws on the fan cover and remove.

3. Unscrew the nut on the fan motor shaft.

4. Pull the fan blade towards you to remove. NOTE: Ensure that you refit the retaining clip on the motor shaft during reinstallation.


5. Carefully disconnect wiring connectors from the fan motor spades. (Note: Take a photo of the wiring positioning/location before disconnecting) Be careful not to damage the connector. Remove the retaining clip from the fan motor.


6. Use a flat bladed screwdriver to prize open the clip on the crossbar to release the fan motor.

7. Twist the fan motor and pull towards you to release.


8. When assembling, repeat steps in reverse order.